To choose Siemens products, you should pay attention to the type of system, production series, manufacturer's recommendation and your local standards. The following information is to show an overview and sharing experiences. Finally, you should get updated information from the official website of the company or one of the product distributors and technical service providers in your area.

Conventional Detectors – Siemens (110 Series, CerberusPRO, Sinteso):

Order Model P.N Note
      Detectors:
1 OP110 S54372-F4-A1 Optical smoke detector, collective
2 HI110 S54372-F9-A1 Heat detector, collective, differential, parameter set A1R
3 HI112 S54372-F10-A1 Heat detector, collective, static, parameter set 1 (A2S) or parameter set 2 (B)
4 OH110 S54372-F11-A1 Multi detector, collective
5 OOH740 S54320-F7-A3 Multi detector, ASA Technology
6 FDOOT241-9M A5Q00015955 Multi detector with conventional base (FDOOT241-9 + FDB201) – Migration kit
7 OOH740-A9-EX S54329-F8-A1 Multi detector, ASA Technology, Ex
8 DO1101A-Ex BPZ:5008010001 Smoke detector, Ex, Old series
9 DT1101A-Ex BPZ:4852140001 Heat detector, Ex, max 50 °C ambient temperature, Old series
10 DT1102A-Ex BPZ:4852270001 Heat detector, Ex, max 70 °C ambient temperature, Old series
      Bases:
1 DB110 S54372-F5-A1 Base, standard, parameter set 1 (A2S), base for OOH740
2 DB110R S54372-F7-A1 Base, with resistor, parameter set 2 (B)
3 DB110RD S54372-F8-A1 Base, with resistor and diode, parameter set 2 (B)
4 DB721D S54319-F15-A1 Base, with diode, parameter set 1 (A2S), base for OOH740
5 FDB201 A5Q00003814 Base, for OOH740-A9-EX & Sinteso detectors, collective, recess wiring
6 FDB201-AA A5Q00012742 Base, for OOH740-A9-EX & Sinteso detector, collective, recess wiring, with x1 micro terminal
7 FDB202 S54319-F3-A1 Base, for OOH740-A9-EX & Sinteso detectors, collective, flat
8 FDB202 A5Q00016446 Base, for OOH740-A9-EX & Sinteso detectors, collective, flat, coloured
9 DB1101A BPZ:4863650001 Base for DO11011-Ex and DT110xA-Ex
      Base attachments:
1 BA720 S54319-F20-A1 Base attachment
2 BA721 S54319-F29-A1 Base attachment, wet, up to IP44
3 FDB291 A5Q00001603 Base attachment, for base FDB2xx
4 FDB295 S54319-F21-A1 Base attachment, wet, for base FDB2xx
5 DBZ1191 BPZ:4540830001 Base for DO11011-Ex and AT110xA-Ex
      Seals:
1 RS720 S54319-F8-A1 Detector base seal
      Designation plates:
1 FDBZ291 A5Q00002621 Designation plate, for base, 62x35mm
2 DBZ1193A BPZ: 4864330001 Designation plate, for base & base attachment, 62x52mm
      Housings:
1 DCA1191 BPZ: 4588560001 Housing, empty, IP56
      Glands:
1 A5Q00004478 A5Q00004478 Cable gland, screwed, M20 x 1.5, for base attachments (BA721)
2 A5Q00004479 A5Q00004479 Back nut, for cable gland M20 x 1.5
      Resistors:
1 PSR720-1 S54319-F16-A1 Resistor, 33k, for parameter set (DB110 & DB721D)
2 PSR720-2 S54319-F17-A1 Resistor, 68k, for parameter set (DB110 & DB721D)
      Terminals:
1 DBZ1190-AA BPZ: 4677080001 Micro terminal, 4 pole, 0.5 mm2
2 DBZ1190-AB BPZ: 4942340001 Connection terminal, 3 pole, 2.5 mm2
      Locking devices:
1 LP720 S54319-F9-A1 Detector locking device
2 FDBZ293 A5Q00005035 Detector locking device, for Ex detector (OOH740-A9-EX)
      Accessories:
1 FDBH291 A5Q00004439 Detector heating set, with 2 micro terminals, for base attachments (BA721)
2 DBZ1194 BPZ: 4677110001 Protective cage
3 MVH1 BPZ: 3496190001 Mounting bracket, for installation in hollow surfaces
      Alarm indicators:
1 FDAI91 S54370-F9-A1 Indicator, door frame
2 FDAI92 S54370-F3-A1 Indicator, surface mounting
3 FDAI92-Ex S54370-F4-A1 Indicator, surface mounting, Ex
4 AI330 BPZ: 3169430001 Base adapter frame for alarm indicator (FDAI92)
5 FDAI93 S54370-F5-A1 Indicator, flush mounting
6 FDAI93-Ex S54370-F6-A1 Indicator, flush mounting, Ex
7 DJZ1193 BPZ: 5302950001 Housing, for alarm indicator (FDAI93)
8 BPZ: 2473130001 BPZ: 2473130001 Washer, for alarm indicator (FDAI93)

Addressable Detectors – Siemens (Cerberus PRO - EN):

Order Model P.N Note
      Detectors:
1 OP720 S54310-F1-A1 Smoke detector
2 HI720 S54310-F3-A1 Heat detector, static
3 HI722 S54310-F4-A1 Heat detector, static & rate of rise
4 OH720 S54310-F2-A1 Multi detector
5 OOH740 S54320-F7-A3 Multi detector, ASA Technology, with 3 parameter sets
6 OOHC740 S54320-F8-A3 Multi detector, ASA Technology, Fire & CO
7 OOH740-A9-EX S54329-F8-A1 Multi detector, ASA Technology, Fire & CO, Ex
      Bases:
1 DB721 S54319-F11-A1 Base, with screw terminals
2 DB722 S54319-F19-A1 Base, with seal and screwless terminals, marine approved
3 DBS720 S54319-F5-A1 Sounder Base
4 FDB221 A5Q00001664 Base, for Ex detector (OOH740-A9-EX) - addressable
      Base attachments:
1 BA720 S54319-F20-A1 Base attachment
2 BA721 S54319-F29-A1 Base attachment, wet, up to IP44, base for OOH740
3 FDB291 A5Q00001603 Base attachment, for base FDB2xx
4 FDB295 S54319-F21-A1 Base attachment, wet, for base FDB2xx
      Seal:
1 RS720 S54319-F8-A1 Detector base seal
      Designation plate:
1 FDBZ291 A5Q00002621 Designation plate, for base, 62x35mm
2 DBZ1193A BPZ: 4864330001 Designation plate, for base & base attachment, 62x52mm
      Housing:
1 DCA1191 BPZ: 4588560001 Housing, empty, IP56
      Glands:
1 A5Q00004478 A5Q00004478 Cable gland, screwed, M20 x 1.5, for base attachments (BA721)
2 A5Q00004479 A5Q00004479 Back nut, for cable gland M20 x 1.5
      Terminals:
1 DBZ1190-AA BPZ: 4677080001 Micro terminal, 4 pole, 0.5 mm2
2 DBZ1190-AB BPZ: 4942340001 Connection terminal, 3 pole, 2.5 mm2
      Locking devices:
1 LP720 S54319-F9-A1 Detector locking device
2 FDBZ293 A5Q00005035 Detector locking device, for Ex detector (OOH740-A9-EX)
      Test tools:
1 FDUL221 A5Q00004397 Line (loop) tester
      Accessories:
1 FDBH291 A5Q00004439 Detector heating set, with 2 micro terminals, for base attachments (BA721)
2 DBZ1194 BPZ: 4677110001 Protective cage
3 MVH1 BPZ: 3496190001 Mounting bracket, for installation in hollow surfaces
      Alarm indicators:
1 FDAI91 S54370-F9-A1 Indicator, door frame, conventional in parallel
2 FDAI92 S54370-F3-A1 Indicator, surface mounting, conventional in parallel
3 FDAI92-Ex S54370-F4-A1 Indicator, surface mounting, conventional in parallel, Ex
4 FDCAI221 S54370-F10-A1 Indicator, surface mounting, addressable
5 AI330 BPZ: 3169430001 Base adapter frame for alarm indicator (FDAI92 & FDCAI221)
6 FDAI93 S54370-F5-A1 Indicator, flush mounting, conventional in parallel
7 FDAI93-Ex S54370-F6-A1 Indicator, flush mounting, conventional in parallel, Ex
8 DJZ1193 BPZ: 5302950001 Housing, for alarm indicator (FDAI93)
9 BPZ: 2473130001 BPZ: 2473130001 Washer, for alarm indicator (FDAI93)

Addressable Detectors – Siemens (Sinteso - EN):

Order Model P.N Note
      Detectors:
1 FDO221 A5Q00001565 Smoke detector (C-Line)
2 FDO241 A5Q00004811 Smoke detector (S-Line), ASA Technology
3 FDO241 A5Q00016441 Smoke detector (S-Line), ASA Technology, coloured
4 FDT221 A5Q00001567 Heat detector (C-Line)
5 FDT241 A5Q00004812 Heat detector (S-Line), ASA Technology
6 FDT241 A5Q00016445 Heat detector (S-Line), ASA Technology, coloured
7 FDOOT221 A5Q00001566 Multi detector (C-Line)
8 FDOOT221 A5Q00016442 Multi detector (C-Line), coloured
9 FDOOT241-9 A5Q00004813 Multi detector (S-Line), ASA Technology
10 FDOOT241-9 A5Q00016443 Multi detector (S-Line), ASA Technology, coloured
11 FDOOTC241 S54311-F1-A1 Multi detector (S-Line), ASA Technology, CO Fire
12 FDX291 S54319-F2-A1 Dummy detector, To cover the base without detector
13 FDOOT241-A9-EX S54329-F7-A1 Multi detector, ASA Technology, Fire, Ex
      Bases:
1 FDB221 A5Q00001664 Base - addressable
2 FDB221-AA A5Q00012741 Base – addressable, with x1 micro terminal
3 FDB222 S54319-F1-A1 Base – addressable, flat
4 FDB222 A5Q00016447 Base – addressable, flat, coloured
      Base attachments:
1 FDB291 A5Q00001603 Base attachment, for base FDB2xx
2 FDB291 A5Q00016448 Base attachment, for base FDB2xx, coloured
3 FDB293 A5Q00003945 Base attachment, wet, for base FDB2xx
4 FDB295 S54319-F21-A1 Base attachment, wet, for base FDB2xx
      Designation plate:
1 FDBZ291 A5Q00002621 Designation plate, for base, 62x35mm
2 DBZ1193A BPZ: 4864330001 Designation plate, for base & base attachment, 62x52mm
      Housing:
1 DCA1191 BPZ: 4588560001 Housing, empty, IP56
      Glands:
1 A5Q00004478 A5Q00004478 Cable gland, screwed, M20 x 1.5, for base attachments (FDB293 & FDB295)
2 A5Q00004479 A5Q00004479 Back nut, for cable gland M20 x 1.5
      Terminals:
1 DBZ1190-AA BPZ: 4677080001 Micro terminal, 4 pole, 0.5 mm2
2 DBZ1190-AB BPZ: 4942340001 Connection terminal, 3 pole, 2.5 mm2
      Locking devices:
1 FDBZ293 A5Q00005035 Detector locking device
      Test tools:
1 FDUL221 A5Q00004397 Line (loop) tester
      Accessories:
1 FDBH291 A5Q00004439 Detector heating set, with 2 micro terminals, for base attachments (FDB293 & FDB295)
2 FDZ291 A5Q00004814 Detector dust cap
3 DBZ1194 BPZ: 4677110001 Protective cage
4 FDBZ294 A5Q00023040 Protective cage, EMC
5 MVH1 BPZ: 3496190001 Mounting bracket, for installation in hollow surfaces
      Alarm indicators:
1 FDAI91 S54370-F9-A1 Indicator, door frame, conventional in parallel
2 FDAI92 S54370-F3-A1 Indicator, surface mounting, conventional in parallel
3 FDAI92-Ex S54370-F4-A1 Indicator, surface mounting, conventional in parallel, Ex
4 FDCAI221 S54370-F10-A1 Indicator, surface mounting, addressable
5 AI330 BPZ: 3169430001 Base adapter frame for alarm indicator (FDAI92 & FDCAI221)
6 FDAI93 S54370-F5-A1 Indicator, flush mounting, conventional in parallel
7 FDAI93-Ex S54370-F6-A1 Indicator, flush mounting, conventional in parallel, Ex
8 DJZ1193 BPZ: 5302950001 Housing, for alarm indicator (FDAI93)
9 BPZ: 2473130001 BPZ: 2473130001 Washer, for alarm indicator (FDAI93)

Special Detectors – Siemens (CerberusPRO, Sinteso):

Order Model P.N Note
      Flame Detectors (non-Ex):
1 FDF221-9 A5Q00003902 Flame detector, Infrared (IR), phased out
2 FDF241-9 AQ00003006 Flame detector, Infrared (IR3)
3 FDFB291 A5Q00003310 Base, for FDF2x1-9
4 MV1 BPZ: 3950450001 Mounting bracket, fixed, for FDF2x1-9
5 MWV1 BPZ: 3674840001 Mounting bracket, adjustable, for FDF2x1-9
6 DFZ1190 BPZ: 5302660001 Rain hood, metal, for FDF2x1-9
7 FDFZ241 S54330-N4-A1 Rain hood, plastic, for FDF2x1-9
      Flame Detectors (Ex):
1 DF1101-Ex BPZ: 5166750001 Flame detector, Infrared (IR3), Ex
2 DFB1190 BPZ: 5165360001 Base, for DF1101-Ex
3 MV1 BPZ: 3950450001 Mounting bracket, fixed, for FDF2x1-9
4 MWV1 BPZ: 3674840001 Mounting bracket, adjustable, for FDF2x1-9
5 DFZ1190 BPZ: 5302660001 Rain hood, metal, for FDF2x1-9
6 FDFZ241 S54330-N4-A1 Rain hood, plastic, for FDF2x1-9
      Beam Detector (FDL241-9):
1 FDL241-9 AQ00002298 Beam detector, phased out
2 FDLB291 A5Q00003941 Base, for FDL241-9
3 DLR1191 BPZ: 4787710001 Reflector, 20-100m, for FDL241-9
4 DLR1192 BPZ: 4788490001 Reflector, 30-65m, for FDL241-9
5 DLR1193 BPZ: 4787840001 Reflector, 10-30m, for FDL241-9
6 DLF1191-AA BPZ: 4933030001 Filter, 7-10m, for FDL241-9
7 DLF1191-AB BPZ: 4933160001 Filter, 5-8m, for FDL241-9
8 DLF1191-AC BPZ: 5221480001 Filter, external light, for FDL241-9
9 DLH1191A BPZ: 4787970001 Detector heating, for FDL241-9
      Beam Detector (FDL242):
1 FDL242 S54331-F10-A1 Beam detector
2 FDLRA242-W S54331-B25-A1 Holder, for FDL242, wall, white
3 FDLRA242-B S54331-B25-A2 Holder, for FDL242, wall, black
4 FDLRL242 S54331-S10-A1 Reflector kit, for FDL242, long distance
5 FDLRLA242 S54331-B23-A1 Reflector, for FDL242, long distance
6 FDLRSA242 S54331-B22-A1 Reflector, for FDL242, short distance
7 FDLR242 S54331-B21-A1 Reflector, for FDL242
8 FDLH242 S54331-B20-A1 Detector heating unit, for FDL242
9 FDLRH242-W S54331-B28-A1 Reflector heating unit, for FDL242, white
10 FDLRH242-B S54331-B28-A2 Reflector heating unit, for FDL242, black
11 FDLZ242 S54331-B24-A1 Protective cage, for FDL242
      Air Samplings:
1 FDA221 S54333-F15-A1 Air sampling detector, up to 500 m2
2 FDA241 S54333-F17-A1 Air sampling detector, up to 800 m2
3 FDA261 S54333-F101-A1 Air sampling detector, up to 3600 m2
4 FDA262 S54333-F102-A1 Air sampling detector, up to 6700 m2
5 FDCC221S S24218-A201-A2 Module, communication interface, for FDA221 & FDA241
6 FDAZ295 S54333-B105-A1 Module, Relay, for FDA261 & FDA262
7 FDAZ296 S54333-B106-A1 Module, 4...20mA, for FDA261 & FDA262
8 FDAZ292 S54333-C92-A1 Filter box, for FDA2x1 & FDA262
      Duct detector set (FDBZ290):
1 FDBZ290 S54319-S32-A1 Air sampling duct kit
2 FDBZ290-AD S54319-B34-A1 Mounting bracket, for FDBZ290
3 FDBZ290-AA S54319-B33-A1 Tube, air flow, 0.6 m, for FDBZ290
4 FDBZ290-AB S54319-B33-A2 Tube, air flow, 1.5 m, for FDBZ290
5 FDBZ290-AC S54319-B33-A3 Tube, air flow, 2.8 m, for FDBZ290
6 FDBZ292-AD A5Q00021367 Seal, for tubes FDBZ290-xx
7 PSR720-2 S54319-F17-A1 Resistor, 68k, for parameter set (DB110 & DB721D)
* OOH740 S54320-F7-A3 Multi detector, ASA Technology, CerberusPRO
** DB110 S54319-F5-A1 Base, conventional
*** DB721 S54319-F11-A1 Base, addressable
**** DB721D S54319-F15-A1 Base, addressable
* FDOOT241-A9 S54310-F11-A1 Multi detector, ASA Technology, Sinteso
** FDB202 S54319-F3-F1 Base, conventional
*** FDB222 S54319-F1-A1 Base, addressable
      Duct detector set (FDBZ292):
1 FDBZ292 A5Q00021362 Air sampling duct kit
2 FDBZ292-AF A5Q00021369 Mounting bracket, for FDBZ292
3 FDBZ292-AA A5Q00021363 Tube, air flow, 0.6 m, for FDBZ292
4 FDBZ292-AB A5Q00021364 Tube, air flow, 1.5 m, for FDBZ292
5 FDBZ292-AC A5Q00021366 Tube, air flow, 2.8 m, for FDBZ292
6 FDBZ292-AD A5Q00021367 Seal, for tubes FDBZ292-xx
* DO1104A BPZ:5090640001 Smoke detector, CerberusPRO (Synova, Algorex)
** DB1101A 4863650001 Base
* FDOOT241-A9 S54310-F11-A1 Multi detector, ASA Technology, Sinteso
** FDB201-AA A5Q00012742 Base, collective
*** FDB221-AA A5Q00012741 Base, addressable
      Glands:
1 A5Q00004478 A5Q00004478 Cable gland, screwed, M20 x 1.5, for base attachments (BA721)
2 A5Q00004479 A5Q00004479 Back nut, for cable gland M20 x 1.5
      Terminals:
1 DBZ1190-AB BPZ: 4942340001 Connection terminal, 3 pole, 2.5 mm2
       