To choose Siemens products, you should pay attention to the type of system, production series, manufacturer's recommendation and your local standards. The following information is to show an overview and sharing experiences. Finally, you should get updated information from the official website of the company or one of the product distributors and technical service providers in your area.
Conventional IO Modules – Siemens (Sinteso, CerberusPRO (EN), Cerberus FIT):
Order | Model | P.N | Note |
Modules: | |||
1 | FCA1209-Z1 | S54400-B124-A1 | Output card, 230VAC- 5A or 30VDC-5A |
2 | DCA1192A | BPZ: 5081200001 | Module, electronic unit for DC1192 |
Safety barrier: | |||
1 | SB3 | BPZ: 4837400001 | Safety barrier, Ex |
Housings: | |||
1 | FDCH221 | S54312-F3-A1 | Housing, IP65 |
2 | DCA1191 | BPZ: 4588560001 | Housing (empty), IP56 |
3 | DCA1191-AB | BPZ: 5463150001 | Housing (empty), IP56, deep cover, with support plate |
Glands: | |||
1 | A5Q00004478 | A5Q00004478 | Cable gland, M20x1.5 |
2 | A5Q00004479 | A5Q00004479 | Cable gland back nut, M20 |
Resistors: | |||
1 | EOL22(Ex) | BPZ: 5162220001 | End of Line (line termination), Ex |
Terminals: | |||
1 | DBZ1190-AB | BPZ: 4942340001 | Connection terminal, 3 pole, 2.5 mm2 |
2 | DBZ1190-AA | BPZ: 4677080001 | Micro terminal, 4 pole, 0.5 mm2 |
Accessories: | |||
1 | Z3I410 | BPZ: 4837660001 | Installation set, for safety barrier (SB3) |
Addressable IO Modules – Siemens (Sinteso, CerberusPRO (EN), Cerberus FIT):
Order | Model | P.N | Note |
Modules: | |||
1 | FDCL221 | A5Q00004011 | Line separator, FDnet & C-NET |
2 | FDCL221-M | S54312-F6-A1 | Line separator, Multi, FDnet & C-NET |
3 | FDCI221 | S54312-F1-A1 | Input module, 1x input, FDnet & C-NET |
4 | FDCI222 | A5Q00001984 | Input module, 4x inputs, FDnet & C-NET |
5 | FDCIO221 | S54312-F2-A1 | Input/Output module, 1x input, 1x output, FDnet & C-NET |
6 | FDCIO222 | A5Q00002369 | Input/Output module, 4x input, 4x output, FDnet & C-NET |
7 | FDCIO224 | A5Q00018689 | Input/Output module, 4x input, 4x output, VdS, extinguishing interface, FDnet & C-NET |
8 | FDCI723 | S54322-F6-A1 | Zone module, external powered, C-NET |
9 | FDCIO223 | S24218-B102-A1 | Transponder module, 2x inputs (detector line) or x output (control line), FDnet & C-NET |
Safety barrier: | |||
1 | FDCL221-Ex | S54329-F4-A1 | Safety barrier (Line adapter), Ex, FDnet & C-NET |
Housings: | |||
1 | FDCH221 | S54312-F3-A1 | Housing, IP65 |
2 | FDCH222 | S54329-F10-A1 | Housing, installation box for barrier (FDCL221-Ex), IP66 |
Glands: | |||
1 | A5Q00004478 | A5Q00004478 | Cable gland, M20x1.5 |
2 | A5Q00004479 | A5Q00004479 | Cable gland back nut, M20 |
Terminals: | |||
1 | DBZ1190-AB | BPZ: 4942340001 | Connection terminal, 3 pole, 2.5 mm2 |
2 | DBZ1190-AA | BPZ: 4677080001 | Micro terminal, 4 pole, 0.5 mm2 |